Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phlebology ; 35(8): 614-622, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32375605

RESUMO

BACKGROUND: The intracavitary electrocardiogram (IC-ECG) method has been used for the tip location of central venous access devices for the advantage of being safe, accurate and highly cost effective. However, long-term follow-up is rare. This randomized clinical trial aimed to evaluate the long-term complications of peripherally inserted central catheters (PICCs) positioned by the IC-ECG method. METHODS: We randomized 2250 patients who needed PICC placement to either a landmark length estimation supplemented by IC-ECG positioned group (ECG group) or the traditional landmark length estimation alone group (control group) in a 2:1 allocation. Post-procedural chest X-rays were applied to confirm tip position. Follow-up was performed monthly to six months. Standard statistics analyses were performed with the SAS 9.13 software, and p < 0.05 was considered significant. RESULTS: As evaluated by post-procedural chest X-ray, tip location in the ECG group had a first-attempt success (catheter tip located at optimal position) of 91.7% (95% confidence interval (CI): 90.3%-93.1%), significantly higher than 78.9% (95% CI: 76.0%-81.9%) observed in the control group (p < 0.001). At six-month follow-up, in the control group, frequency of total complications was 9.5%, including the exit site infection (4.0%), phlebitis (1.3%), deep venous thrombosis (1.5%), liquid extravasation (2.9%) and mechanical failure (1.9%). The IC-ECG group had significantly lower rates of complications (6.4%, p < 0.001), including the exit site infection (2.7%, p > 0.05), phlebitis (1.1%, p > 0.05), deep venous thrombosis (1.2%, p > 0.05), liquid extravasation (2.4%, p > 0.05) and mechanical failure (1.2%, p > 0.05). In the univariable logistic regression analysis, ECG method, other diseases and upper arms were the independent protective factors, and the number of adjustment procedures (n ≥ 2) were the independent risk factors of the complications. CONCLUSIONS: The intra-procedural tip location by IC-ECG is more safe and accurate than the traditional method of verifying tip location only post-procedurally, by chest X-ray.


Assuntos
Cateterismo Venoso Central , Cateterismo Periférico , Cateteres Venosos Centrais , Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Eletrocardiografia , Humanos , Radiografia
2.
J Vasc Access ; 20(5): 524-529, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30596472

RESUMO

INTRODUCTION: Ultrasound-guided venipuncture and tip location by intracavitary electrocardiogram have many advantages during the insertion of peripherally inserted central catheters, both in terms of safety and cost-effectiveness. Recently, a new tip-conductive peripherally inserted central catheters and new Doppler ultrasound device integrated with intracavitary electrocardiogram have been introduced into clinical practice in China. A randomized multicenter study (clinical trial no. NCT03230357) was performed to verify the feasibility and accuracy of intracavitary electrocardiogram, as performed with this new peripherally inserted central catheters and device. METHODS: Our study enrolled a total of 2250 adult patients in 10 different Chinese hospitals. The patients were randomly assigned to either the study group (intracavitary electrocardiogram) or the control group (anatomical landmark guidance) in a 2:1 allocation. Ultrasound was used in both groups for venipuncture and tip navigation. All patients underwent chest X-ray after the procedure to verify the position of the catheter tip. RESULTS: No insertion-related complications were reported in either group. In the study group, first-attempt successful tip location was 91.7% (95% confidence interval: 90.3%-93.1%), significantly higher than 78.9% (95% confidence interval: 76.0%-81.9%) observed in the control group (p < 0.001). As evaluated by post-procedural chest X-ray, tip location in the study group had a sensitivity of 99.3% (95% confidence interval: 98.8%-99.7%), significantly higher than 86.8% (95% confidence interval: 84.4%-89.2%) observed in the anatomical landmark group (p < 0.001). CONCLUSION: These results indicated that during peripherally inserted central catheters insertion in adult patients, tip location with intracavitary electrocardiogram guidance, as carried out by a new tip-conductive peripherally inserted central catheters and intracavitary electrocardiogram integrated ultrasound device, was more effective and more accurate than tip location using anatomical landmarks.


Assuntos
Cateterismo Periférico/instrumentação , Cateteres de Demora , Pressão Venosa Central , Eletrocardiografia/instrumentação , Transdutores , Ultrassonografia Doppler/instrumentação , Ultrassonografia de Intervenção/instrumentação , Idoso , Pontos de Referência Anatômicos , Cateterismo Periférico/efeitos adversos , China , Eletrocardiografia/métodos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...